Compliance

The Dincel product is at the forefront of innovative construction by focusing on rigorous testing to meet and exceed industry standards.

To understand how Dincel complies with the requirements of Civil and Transport authorities (such as a minimum 120 year life and concrete compaction), please download the following document:

Otherwise, individual test reports and certifications may be downloaded below:

Dincel has undergone extensive large-scale fire testing to demonstrate safety in a variety of scenarios. The tests and assessments were performed by reputable NATA accredited authorities such as CSIRO and Warringtonfire.

The Dincel formwork material is comprised of certain additives which enhances fire performance. In the event of a fire, the material safely chars and intumesces (it does not form molten droplets or spread fire). The solid concrete within provides the necessary fire rating.

Authority Standard/Report Type Results Report/Certificate No.

Warringtonfire

Last Updated: 23-01-2020
AS5637.1 Classification Report (Test to AS ISO 9705)

Group Number - 1
Smoke Growth Rate (SMOGRA) - 14

Omnii Consulting Fire Engineers

Last Updated: 19-04-2020
Evidence of Suitability Report (AS5113 test review)

Dincel is suitable where a non-combustible external wall is required.

CSIRO

Last Updated: 27-11-2019
AS1530.8.2-2018 Assessment Report Dincel bushfire resistance of BAL - FZ

CSIRO

Last Updated: 14-01-2020
AS1530.4-2014 Assessment Report 200mm Dincel - 240/240/240 FRL

Warringtonfire

Last Updated: 04-11-2019
Assessment Letter Dincel polymer webs do not adversely affect the FRL performance of the wall

Warringtonfire

Last Updated: 23-01-2020
AS1530.4-2014 Assessment Report - Wall Penetrations No requirement to cut away Dincel skin underneath Hilti fire collars for penetrations

Warringtonfire

Last Updated: 23-01-2020
AS1530.4-2014 Assessment Report - Wall Joints No requirement to cut away Dincel skin underneath Hilti fire rated caulking for wall joints

TÜV SÜD Asia Pacific

Last Updated: 14-02-2019
BS 6853:199 Test Report Fumes generated by Dincel burning test was under international toxicity thresholds/limits

Based on tests completed at CSIRO’s Acoustic Laboratories, National Acoustic Laboratories and laboratory test data, Dincel Structural Walls 110mm, 155mm and 200mm and 275mm have proven acoustic performance ideal for applications such as sound walls.

Authority Standard/Report Type Results Report/Certificate No.

Day Design

Last Updated: 02-07-2019
Acoustic Opinion Acoustic values for various 110mm Dincel walling system arrangements

Day Design

Last Updated: 02-07-2019
Acoustic Opinion Acoustic values for various 155mm Dincel walling system arrangements

Day Design

Last Updated: 02-07-2019
Acoustic Opinion Acoustic values for various 200mm Dincel walling system arrangements

Dincel Walls have been tested for Volatile Organic Compounds (VOC), which have been measured to be 25 times less than the recommended Green Star environmental threshold making it a proven choice for sustainable construction.

Authority Standard/Report Type Results Report/Certificate No.

CETEC

Last Updated: 22-01-2020
ASTM D5116-97 Test Certificate Volatile Organic Compounds (VOCs) 25 times less than the Australian Green Star rating threshold at time of manufacture. VOCs below detection level after 30 days

Dincel Walls with concrete infill can create earthquake, cyclone and hurricane proof walls through ductile composite action, thus achieving greater safety than offered by concrete alone.

Authority Standard/Report Type Results Report/Certificate No.

University of Technology Sydney (UTS)

Last Updated: 04-02-2020
Analysis and Test Report Dincel's suitability to resist earthquakes with a magnitude of up to 9.0 on the Richter scale

Dincel panel joints when filled with are concrete are waterproof as confirmed by CSIRO for up to 6m of water head pressure.

Authority Standard/Report Type Results Report/Certificate No.

CSIRO

Last Updated: 07-01-2019
Waterproof Testing to AS3740, ASTM E514, AS/NZS 4347.1, ASTM E96/M

Dincel panels along with snap-joints when filled with concrete is waterproof for up to 6m of water head pressure.

Dincel Structural Walling is a concrete wall encapsulated by permanent polymer formwork. If the polymer formwork of Dincel-Wall is removed for any reason, the remaining component is the concrete which is in compliance with the Concrete Structures Code AS 3600 (as certified by The University of New South Wales and The University of Technology Sydney).

Authority Standard/Report Type Results Report/Certificate No.

University of New South Wales (UNSW)

Last Updated: 23-01-2020
Structural Engineering Certification Concrete and steel reinforcement within Dincel can be designed to AS3600, Eurocode and other relevant design codes. Certification of Dincel design principles

University of Technology Sydney (UTS)

Last Updated: 24-05-2019
Structural Engineering Certification Concrete and steel reinforcement within Dincel can be designed to AS3600, Eurocode and other relevant design codes. Certification of Dincel design principles

University of Technology Sydney (UTS)

Last Updated: 21-01-2021
Technical Report

Testing and analysis of Dincel 275 for flexural strength, interface shear and stiffness. Confirmation that for suitable applications, Dincel 275 can be designed and installed without the use of steel reinforcement bars.

All Dincel polymer panels and accessories are BEP (Best Environmental Practices) certified. The polymer PVC used is heavy metal stabiliser and plasticiser free.

Authority Standard/Report Type Results Report/Certificate No.

ApprovalMark International

Last Updated: 22-01-2020
BEP Certificate Best Environmental Practice (BEP) Approval

Design & Supply
for all your Civil Infrastructure needs.

Let's get started Organise a product presentation
Design, Supply and Install for all your Civil Infrastructure needs